<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>22103</ErrorNumber>
<ErrorFamily>Autoloader 2</ErrorFamily>
<ErrorMessage>
ALE2: Sum value from focus laser is too low, check media setup
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>ThermoFlex</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
This may be due to incorrect media setup, the debris nozzle out of place or the media
being loaded incorrectly so that the head is not fully over the media while zeroing.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
None.
</text></DescriptionText>
</OperatorAction>
<Cause>
After focussing the sum value seen by the focus system is too low.
</Cause>